0.0
0 Reviews
One year warranty

Buckleys Dry Roof Pro’ High-Voltage Flat Roof Leak Detector

SKU: CP102724
Model: Dry Roof Pro’
Product Condition: Certified Pre-owned
$4,799.95

Buckleys Dry Roof Pro’ high-voltage detector for locating leaks, defects, and porosity in non-conductive flat roof membranes with adjustable DC output, sensitivity control, and audible/visual fault indication.

Read more
Estimated delivery: 3 days
One year warranty
Free return within 30 days of purchase.
Contact
Have a question ? Ask an expert
Product Description

High-voltage detection of hidden leaks in non-conductive flat roof membranes

Leaks in non-conductive flat roof coverings cannot be confirmed by visual inspection alone. Detection requires a controlled high-voltage method that reveals faults by establishing a path to earth. The Buckleys Dry Roof Pro’ is designed for this purpose, providing regulated DC output, adjustable sensitivity, and clear fault indication.

Detection of faults through electrical path to earth

  • Identifies defects by completing an electrical circuit through the membrane
  • Indicates faults with audible alarm and visual signal
  • Detects pinholes, cracks, and coating discontinuities
  • Operates on non-conductive roofing materials

Controlled voltage and sensitivity

The Buckleys Dry Roof Pro’ applies a stabilised DC output with adjustable voltage and sensitivity. Test voltage may be set directly or calculated from coating thickness using a defined formula.

Use across flat roof inspection

  • Inspection of bitumen, asphalt, and single-ply membranes
  • Detection of faults not visible at the surface
  • Use in inspection and maintenance of flat roof systems
Specifications
Specifications
MPN DRP01
Product Condition Certified Pre-owned
Shipping Length (in.) 22
Shipping Width (In.) 10
Shipping Height (In.) 25
Condition Type Certified Pre-Owned
Item Returns This item can be returned
SpecificationValue
ManufacturerBuckleys (UVRAL) Ltd
ModelDry Roof Pro’
ApplicationDetection of leaks, defects, and porosity in non-conductive flat roof coverings
Output Voltage Range2 to 40 kV DC
Output Voltage Steps2 to 10 kV in 10 V steps; 10.1 to 40 kV in 100 V steps
Maximum Output CurrentLess than 1 mA continuous
DC Sensitivity Range10 µA to 450 µA
Default DC Sensitivity350 µA
PolarityPositive
Test Voltage FormulaNACE SP-02-74
Coating Thickness Range64 µm to 25.6 mm
Battery Type4 x D-cell batteries
Typical Operating Time8 hours at 40 kV
Unit Dimensions172 mm x 85 mm x 235 mm
Unit Weight1.64 kg
Handle Weight720 g
Temperature Range0 °C to +40 °C
Maximum Relative Humidity80% non-condensing
AltitudeUp to 2000 m
What's in the box?
  • 1 x Buckleys Dry Roof Pro’ detector unit
  • 1 x Probe handle
  • 1 x Interconnecting lead
  • 1 x 5 m earth lead on reel
  • 1 x 50 m earth extension lead
  • 1 x 450 mm phosphor-bronze electrode
  • 2 x Drum brush electrodes
  • 1 x 75 mm pointed probe electrode
  • 2 x 332 mm insulated mid-section extension rods
  • 1 x 332 mm insulated end-section extension rod
  • 1 x Knurled thumb-nut
  • 1 x Carry bag with shoulder strap
  • 1 x User instruction and calibration certificate
  • 1 x Hard transport case
Technical Resources
Related Posts

No Related Posts

Reviews
Write Your Own Review
You're reviewing: Buckleys Dry Roof Pro’ High-Voltage Flat Roof Leak Detector
loader
Loading...

You submitted your review for moderation.