Whether you’re tackling routine energy audits or complex power quality diagnostics, AEMC’s PowerPad line brings precision and flexibility to the field. These rugged, three‑phase power quality analyzers are purpose-built for engineers, contractors, utility professionals, and facilities teams looking for accurate measurement, intuitive data capture, and deep analysis.
The 8333 is an easy-to-use, compact Class B analyzer with:
Inputs: 3 current / 4 voltage channels, capable of single- or three-phase diagnostics
Sampling: 256 samples per cycle, plus DC
Recording Limits: Up to 12 screen snapshots, 50 transients, and 4,000 alarm events across 10 parameters
Safety Rating: 600 V CAT IV / 1000 V CAT III; IP53
Basic commercial or industrial installations
Long‑term monitoring of voltage, current, harmonics, and power factor
Entry-level diagnostics where portability and ease-of-use matter
Stepping up in memory and functionality, the PowerPad 8336 adds:
Inputs: 5 voltage / 4 current channels for more flexibility
Capacity: 2 GB internal memory, capture up to 210 transients, 10,000 alarms, and inrush events
Features: Real-time waveforms, harmonic and flicker analysis, phasor diagrams, automatic probe scaling
Warranty: 3‑year warranty with online registration within 30 days of purchase
Comprehensive power quality audits
Evaluating harmonics, flicker, imbalances, inrush behavior
Tasks requiring trend data over extended periods
The PowerPad 8345 brings cutting-edge performance with:
Certification: IEC 61000‑4‑30 Edition 3 Class A — highest accuracy standard
Advanced Diagnostics: Harmonics up to order 127, interharmonics, shockwave capture (up to 12 kV at 500 ns), true inrush monitoring
Analysis Tools: Energy valuation, MSV detection, trend measurement every 200 ms, alarm emails, VNC remote control via Wi‑Fi/Ethernet, web‑server interface
Durability & Connections: IP54-rated case, power adapter for line power (up to 1000 V AC/DC), accepts full PowerPad sensor range
Power quality compliance testing and certification
Distributed facilities, renewable installations, industrial substations
Advanced diagnostics where transient, harmonic, and network signaling detection are required
Model
Class Rating
Input Channels (V/A)
Memory / Captures
Highlights
Rugged Rating
8333
Class B IEC 61000‑4‑30
4V / 3A
4,000 alarms, 50 transients, 12 snapshots
Basic waveform and PQ logging
IP53; 600 V CAT IV
8336
Class B
5V / 4A
10,000 alarms, 210 transients, inrush logs
Real‑time waveforms, extensive alarm support
8345
Class A
Extended trend, shockwave, inrush, alarms
Full compliance, remote control, web‑server
IP54; 1000 V CAT IV
8333: Monitor basic power quality at facilities, light industrial sites, or buildings that don't yet require Class A precision.
8336: Medium-scale quality audits—ideal for general manufacturing, data centers, or facilities with complex equipment and startup events.
8345: Regulatory compliance, utility-grade analysis, or environments demanding native Class A accuracy, high-speed transient capture, and remote diagnostics.
Whether you need entry-level monitoring or advanced Class A diagnostics, AEMC’s PowerPad series offers the flexibility to match your application. Browse our selection today or reach out to our team for help finding the right analyzer for your facility or project.