Meet the Fluke 1734 Three-Phase Energy Logger – your go-to tool for easy, accurate energy monitoring. Track voltage, current, power, and more with WiFi connectivity and real-time data via the Fluke Connect® app. Perfect for spotting energy waste and optimizing your facility’s efficiency. Ready to take control of your energy use?
100 V to 500 V using safety plug input when powering from the measurement circuit
00 V to 240 V using standard power cord (IEC 60320 C7)
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
≥ 68.2 % (in accordance with energy efficiency regulations)
< 0.3 W only when powered using IEC 60320 input
50/60 Hz ± 15 %
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
Four hours in standard operating mode, up to 5.5 hours in power saving mode
< 6 hours
16-bit synchronous sampling
10.24 kHz at 50/60 Hz, synchronized to mains frequency
50/60 Hz (42.5 to 69 Hz)
1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ
Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies)
Internal flash memory (not user replaceable)
Typical 10 logging sessions of 8 weeks with 1-minute intervals
Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
IEEE 1459
File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
File transfer and remote control via direct connection or WiFi infrastructure
Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 with WiFi and BLE adapter)
Data download device to PC
4 (3 phases and neutral)
1000 Vrms, CF 1.7
10 MΩ
42.5 Hz - 3.5 kHz
1:1 and variable
1000 V CAT III/600 V CAT IV
3, mode selected automatically for attached sensor
Clamp input: 500 mVrms/50 mVrms; CF 2.8
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
2
0 to ± 10 V dc, 1 reading/s
Format: mx + b (gain and offset) user configurable
User configurable (7 characters, for example, °C, psi, or m/s)
Fluke Connect® 3000 series
1 reading/s
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Instrument: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
-10 °C to +50 °C (14 °F to 122 °F)
-20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
12000 m
IP50 in accordance with EN60529
MIL-T-28800E, Type 3, Class III, Style B
IEC 61010-1 IEC Mains Input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-031: CAT IV 600 V/CAT III 1000 V